Q: Should this RFC define a normative gRPC inference service interface, or defer to a separate RFC?
Status: Open Context: Deferred. gRPC binding requires a separate protobuf service definition. Reserved for a future RFC once a concrete gRPC backend implementation exists and the payload shape is informed by real usage.
Where normative: n/a — pending future RFC or implementation experience
Q: Should the binding declare a streaming mode, and how should partial outputs interact with the atomicity guarantee?
Status: Open Context: Deferred. Streaming is architecturally significant; partial output atomicity is non-trivial. Reserved for a future RFC after the non-streaming binding is stable.
Where normative: n/a — pending future RFC or implementation experience
Q: Should circuit breaking be supported as an optional declaration on the binding?
A: Yes, as an optional declaration on the binding. A circuitBreaker block may be added to a binding declaration with failureThreshold and resetAfter properties. When the circuit is open, dispatch MUST fail with error M01540 (circuit open) rather than retrying. Circuit state is per-binding-per-process; it is not persisted across restarts.
Where normative: RFC-0015 §§4.1 and 10 (circuit-breaker syntax and diagnostic)
Q: Should action-level timeouts be allowed to override binding-level timeouts?
A: Action-level timeout override is allowed. An action that invokes an agent MAY declare agentTimeout: Duration in its action body to override the binding’s timeout: for that specific invocation. The action-level timeout MUST be shorter than or equal to the binding-level timeout; a longer action-level timeout produces warning M01541.
Where normative: RFC-0015 §10 (action timeout ceiling and diagnostic)
Q: Should the binding declaration carry a version field?
A: Yes. The binding declaration MUST carry an explicit version: String field that the module author increments when any binding property changes. Binding version is NOT semver — it is a monotone string used purely for change detection. The lockfile includes the binding version hash.
Where normative: §4 (binding declaration) of RFC-0015
Q: How should read scope be defined — as part of the permissions block or as a separate block?
A: A separate readScope block is introduced in the agent declaration (RFC-0008 §8.10). The permissions block remains write-oriented. readScope declares which entity kinds and fields the agent may read when constructing its prompt context. The runtime MUST enforce readScope at prompt assembly time. An agent with a permissions block but no readScope MUST produce warning M08932.
Where normative: RFC-0008 §8.10 (read scope and diagnostic)